Remove the air damper removing any screws holding the conduit cover or damper cover into place pulling the covers off as well.
Frigidaire side by side fridge and freezer not cooling.
On refrigerators with only one evaporator the evaporator is located in the freezer compartment.
The evaporator fan motor draws air over the evaporator coils and circulates it throughout the freezer.
If the defrost heater assembly is defective frost will continue to accumulate on the evaporator coils and the coils will become plugged with frost.
These vents should never get clogged with ice but if for some reason it does the impaired air circulation will keep the refrigerator section from cooling down.
Check the evaporator coils to determine if they are frosted over.
If the evaporator coils are frosted over the airflow through the coils will be restricted causing the refrigerator not to cool.
On most refrigerators the fan motor will not run when the door is open.
If the evaporator fan is not working the freezer or refrigerator will not cool adequately.
Freezer is cool on bottom as is fridge but neither is effective.
On a side by side freezer fridge the air damper should be located in the upper left corner of the fridge.
Some refrigerators have more than one evaporator fan motor.
My frigidaire side by side refrigerator freezer is not working properly.
If the fan blade does not turn freely replace the fan motor.
To determine if the evaporator fan motor is defective try turning the fan blade by hand.
If this occurs the freezer may still get cold while the refrigerator will not get cold.
The thermostat sensor will be around the damper which you can easily take off.
If the evaporator fan motor is not working the freezer will not cool.
This diy repair guide shows how to replace the defrost sensor also called a defrost thermostat bi metal.
If your side by side refrigerator isn t as cool as it should be and frost is forming in the freezer a failed defrost sensor could be to blame.
If the evaporator fan is not working the freezer or refrigerator will not cool adequately.
To determine if the evaporator fan motor is defective try turning the fan blade by hand.
If the evaporator fan is not working it will not circulate the cold air to the refrigerator compartment.
The evaporator fan motor draws cold air over the evaporator coils and circulates it throughout the freezer.
Tech put in new 3 n 1 relay yesterday and 24 hours later the freezer is not cold enough.
To check the evaporator fan motor open the freezer door and then manually activate the freezer door switch.
Vents between freezer and refrigerator are clogged the vents between the freezer and refrigerating section permit the flow of cold air from the freezer across to the refrigerator.