11 12 to 12 12 4 0 feet above the roof surface continues to 21 12 pitch at 8 0 feet vent caps larger than 12 must be located at least 2 feet above the highest point and 2 feet higher than any portion of the building within a horizontal distance of 10 feet.
Flue height above roof line australia.
The distance between the cowl of the flue and the adjacent roof wall structure should be higher than 2 3 mtr.
To achieve the correct flue height the flue kit must be at least 4 metres in length.
This is for masonry chimneys.
1100mm above roof penetration height.
For a gas vent or type l vent this height must be 2 ft 0 61m or more.
The top of the flue opening should be 3 ft 0 92 m above any roof surface.
Alternatively there must be a minimum distance of 3 meters from any higher section of roof.
The same standard also states that the end of the flue cannot be near any windows or doors so as to prevent expelled air from being pushed back into your home.
The top of the flue must be 60cm.
Flues need to be 600mm higher than the highest part of the roof within 3 metres.
For further information contact the gas safety technical information line on 1800 652 563.
This means that below 38 degree roof pitches that the height of the flue outlet should be at least 1800mm above the roof when not close to the ridge and above 38 degree roof pitches the flue outlet height should be 2300mm horizontally back to the roof flue height figures are given in the table above where the flue is not close to the ridge.
2 australian standard as nzs 2918 2001 requires a minimum flue height of 4 6 metres above the floor on which the woodheater is located.
The location of the flue terminal of a balanced flue appliance room sealed appliance a fan assisted appliance or an appliance designed for outdoor installation shall comply with the figure below.
How far your flue pipe must extend out of your roof depends upon a the minimum height of a flue system within 3m from the highest point of the roof shall be 600mm above that point.
A wood heater installation must meet the australian standard as2918.
Flues that are more than 3 metres away from the highest part of the roof need to be 1000mm above the flue penetration.
Australian standard as nzs 2918 2001 requires a minimum flue height of 4 6 metres above the floor on which the wood heater is located.
Some installations may require even greater flue height to ensure adequate clearance above the roof or ridge line.
A vertical line drawn along the up roof side of the chimney from the roof surface to the top of the chimney flue opening shall be at least 3 ft in height.
Flat roof installation less than 5.