Pressure drop between tees will determine flow to terminal unit water always follows path of least resistance.
Flow diagram chilled water system.
Chilled water flow through the cooling coil is restricted in response to supply air temperatures to the space but the total quantity returned to the chiller remains constant.
A more complex chilled water cooling system configuration can consist of multiple chillers multiple pumps cooling towers heat exchangers and all sorts of valves to redirect flow according to the heat load inside of the building.
Next we ll talk about a couple of different chilled water system configurations.
Chilled water trade names total comfort solution ultimate comfort systems zcooling domestic cold water chilled water trade names total comfort solution zheating domestic hot water.
A refrigeration circuit and a fluid circuit.
The process fluid absorbs heat from what is being cooled and then goes through the chiller where the heat is removed from the fluid and transferred to the ambient air.
At this early stage of the building program the design engineer can write a sequence of operation even if the designer has not firmed up the chilled water system capacity.
Variable primary flow in bypass mode system flow below chiller min flow 250 gpm variable primary flow at 25 system load two way valves control capacity by varying flow of water in coils per chiller system load 50 tons 176kw 50tons 176 kw primary bypass flow 250 gpm 95 l s 150 gpm 9 5 l s delta t 12 of 6 7 oc 100 gpm 44 ºf 6.
If the flow rate in the secondary side is low then some chilled water will flow into the secondary and some will recirculate back to the chillers.
Chilled water system equations evaporator and condenser flow rates sponsored links in a chilled water system the water is cooled down to 40 45 o f 4 7 o c by an centralized evaporator distributed throughout the building in pipes and connected locally to air condition cooling units wherever needed.
B primary chilled water pumps p 1 and p 2 shall be sized for the pressure.
Industrial water or glycol chiller systems contain two main circuits.
2 12 3 central chilled water plant flow diagram.
The single most common problem in chiller piping installations is lack of chilled water flow caused by inadequate system venting.
The chilled water is generated and circulated in the primary side the secondary loops will pull chilled water out of the header to cool the building and then dump the warm return back into the header.
A the above arrangement shall be used for chilled water systems that.
Chilled water cooling systems.
Figure below shows the schematic of the constant flow rate primary system.
The result is repeated flow alarms when the flow switch that is installed in the chiller opens the control circuit stops the chiller and sets the alarm.