I m installing a wood burner as part of this project and the flue has to go through the new flat roof.
Flat roof wood burner external flue regulations.
Anon there are some different requirements for wood burning fireplaces and woodstoves e g.
450 mm 18 in.
The distance between the cowl of the flue and the adjacent roof wall structure should be higher than 2 3 mtr.
D smoke chamber here the smoke gathers before being passed into the flue.
When installing a new twinwall flue system if the flue exits the roof within 600mm horizontally from the ridge high point of the roof then the flue must extend a minimum of 600mm above the ridge.
The purpose of venting systems for wood burning fireplaces and wood stoves seems similar.
Wood burning appliance venting is broken into two primary categories.
In the article above on this page the section titled roof clearances for wood burning fireplaces.
C flue connector connects the fireplace to the flue.
They actually differ a great deal.
The minimum chimney height recommended for minimum performance of wood burning and multi fuel appliances is 4 5 m from the top of the appliance to the top of the chimney.
A flue lining usually made of refractory concrete or impervious clay.
Homes built on varying terrain have their own set of chimney and flue regulations.
E smoke shelf prevents downdraughts.
The flue is not yet in position nor is it likely to be when the roofers return not a great situation i know but i want to plan for the flue as best i can.
Flues that are more than 3 metres away from the highest part of the roof need to be 1000mm above the flue penetration.
Positions where this could be a nuisance should be avoided.
A maximum of 4 bends up to 45ยบ angle is allowed.
Such as its roof tiles or external wall.
Flues need to be 600mm higher than the highest part of the roof within 3 metres.
Or shingle roofs the flue or chimney the regulations.
A flat roof has a pitch of less than 10 degrees.
If the flue exits the roof further down then it must extend high enough to acheive 2 3m of horizontal clearance.
Minimum clearance from combustible material.
The flue will necessarily be quite close to the edge of the flat roof where it abuts.
On 2019 11 21 by anonymous.
B flue must be high enough for sufficient draught around 4 5m in most cases.
The minimum clearance may be reduced by 50 percent to 225 mm 9 in if suitable shielding is installed either on the pipe or on the combustible surface.
As the name implies air cooled systems use air for cooling.
Regarding chimney height codes in the state of florida does the same rule apply to both gas burning fireplace and wood burning.
A flue pipe must never pass through a combustible floor or ceiling or through an attic roof space closet or concealed space.